Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Chinese Journal of Medical Instrumentation ; (6): 132-135, 2019.
Article in Chinese | WPRIM | ID: wpr-772545

ABSTRACT

The work explored the DEHP migration parameters in PVC infusion in clinic,based on the previous research on the test model of DEHP migrated from PVC infusion,to assess the safety of PVC infusion.The leaching solution samples in different conditions were evaluated by analysis of the DEHP in leaching solution using GC-MS under simulated clinical transfusion way.The release behavior of DEHP was significantly affected by the storage time,storage temperature,surrounding temperature,dripping speed,sterilization process,volume of the leaching solution,and the property of the leaching solution.


Subject(s)
Diethylhexyl Phthalate , Pharmacokinetics , Gas Chromatography-Mass Spectrometry , Plasticizers , Pharmacokinetics , Polyvinyl Chloride , Pharmacokinetics , Temperature
2.
Chinese Journal of Medical Instrumentation ; (6): 222-224, 2018.
Article in Chinese | WPRIM | ID: wpr-689827

ABSTRACT

As we all know, DEHP is seriously harmful to human health and consequently has been acquired critical attention. DEHP is able to migrate from PVC medical devices for the non-chemically bound to PVC, thus contact with user and patient. The DEHP migration is influenced by various parameters. In order to assess the security of PVC-tubes medical devices scientifically of DEHP migration, we develop an experimental model by analyzing the parameters comprehensively and systematically, taking into account the clinical practices. For example, assessing the security of DEHP migration from infusion sets by utilizing this model.


Subject(s)
Humans , Diethylhexyl Phthalate , Equipment and Supplies , Models, Theoretical , Plasticizers , Polyvinyl Chloride
3.
Chinese Journal of Medical Instrumentation ; (6): 293-295, 2018.
Article in Chinese | WPRIM | ID: wpr-689806

ABSTRACT

DEHP is largely used in soft PVC products as the plasticizer, which is also widely applied in medical devices. Due to its potential and widespread toxicity and medical devices' specific use, the safety of DEHP's application in medical devices has received extensive attention. In this paper, a comprehensive review of the application and potential toxicity of DEHP in PVC medical devices is made on the basis of the research results all over the world. Besides, the safety evaluation in medical devices is discussed and some possible coping strategies are explored.


Subject(s)
Diethylhexyl Phthalate , Equipment Safety , Equipment and Supplies , Plasticizers , Polyvinyl Chloride
4.
Chinese Circulation Journal ; (12): 165-169, 2016.
Article in Chinese | WPRIM | ID: wpr-487061

ABSTRACT

Objective: To observe the effects of astragaloside IV on myocardial fibrosis and connective tissue growth factor (CTGF) expression in experimental rats with chronic heart failure (CHF). Methods: CHF model was established by abdominal aorta constriction (AAC) and the rats were divided into 5 groups:Sham operation group, the rats received normal saline 2 ml/day, n=10, CHF group, the rats received normal saline 2 ml/day, n=12;Astragaloside IV groups, CHF rats received astragaloside IV at (20, 40, 60) mg/kg respectively and n=12 in each group. All animals were treated for 4 weeks. Hemodynamic indexes were monitored, left ventricular mass index (LVMI) was calculated, morphologic changes of myocardial tissue was observed by HE staining, myocardial ifbrosis degree and collagen volume fraction (CVF) were measured by Masson staining. The mRNA and protein expressions of CTGF were detected by RT-PCR and immunohistochemistry, Western-blot analysis respectivety. Results: Compared with CHF group, 3 Astragaloside IV groups had decreased LVMI and CVF, P Conclusion: Astragaloside IV can inhibit myocardial ifbrosis and improve cardiac function in CHF rats, which might be via inhibiting the over expression of myocardial CTGF.